LUOYANG SANWU CABLE CO.,LTD.

Professional Cable and Conductor Manufacturer

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsAll Aluminium Alloy Conductor

AAAC All Aluminium Alloy Conductor

AAAC All Aluminium Alloy Conductor

    • AAAC All Aluminium Alloy Conductor
    • AAAC All Aluminium Alloy Conductor
    • AAAC All Aluminium Alloy Conductor
    • AAAC All Aluminium Alloy Conductor
  • AAAC All Aluminium Alloy Conductor

    Product Details:

    Place of Origin: Luoyang,China
    Brand Name: Luoyang Sanwu
    Certification: IS09001, IS014001,OHSAS18001. CCC
    Model Number: AAAC

    Payment & Shipping Terms:

    Minimum Order Quantity: 5000m
    Price: Negotiable
    Packaging Details: Export steel or wooden drum
    Delivery Time: 10-25days
    Payment Terms: L/C, T/T, Western Union
    Supply Ability: 10000km per month
    Contact Now
    Detailed Product Description
    Material: All Aluminum Alloy Conductor Application: Overhead Transmission Line
    Voltage: LV,MV,HV Standard: IEC,ASTM,BS,DIN,NFC,CSA
    Type: 55 Sq Mm Aaac Conductor Size: 55 Sq Mm/ 34 Sq Mm
    High Light:

    AAAC All Aluminium Alloy Conductor

    ,

    34 Sq Mm All Aluminium Alloy Conductor

    ,

    55 sq mm aaac conductor

    ASTM IEC BS Bare All Aluminum Alloy Strand Power Electrical Wire Overhead Conductor

     

    AAAC Conductor All Aluminum Alloy Conductor Standard: IEC60889, ASTM B232,BS 215 AAAC Cable can be used in Medium, High and Extra-High voltage transmission lines. AAAC offers better sag performance due to the high strength-to-weight ratio provided by the aluminum-alloy. In addition, AAAC provides a higher corrosion resistance than ACSR conductors.

    Construction
    Standard 6201-T81 high strength aluminum conductors, conforming to IEC61089 Specification, are concentric-lay- stranded, similar in construction and appearance to 1350 grade aluminum conductors. Standard 6201 alloy conductors are similar to other alloy conductors commercially known as Ardival, Aldrey or Almelec. They were developed to fill the need for an economical conductor for overhead applications requiring higher strength than that obtainable with 1350 grade aluminum conductors, but without a steel core. The DC resistance at 20°C of the 6201-T81 conductors and of the standard ACSR of the same diameter are approximately the same. Conductors of the 6201-T81 alloys are harder and, therefore, have a greater resistance to abrasion than conductors of 1350-H19 grade aluminum.

     

    ASTM B399

    Code Name Area Size & Stranding of ACSR with Equal Diameter No. & Diameter of wires Overall Diameter Weight Nominal Breaking Load
    Nominal Actual
    MCM mm2 AWG or MCM Al/Steel mm mm kg/km kN
    Akron 30.58 15.48 6 6/1 7/1.68 5.04 42.7 4.92
    Alton 48.69 24.71 4 6/1 7/2.12 6.35 68.0 7.84
    Ames 77.47 39.22 2 6/1 7/2.67 8.02 108 12.45
    Azusa 123.3 62.38 1/0 6/1 7/3.37 10.11 172 18.97
    Anaheim 155.4 78.65 2/0 6/1 7/3.78 11.35 217 23.93
    Amherst 195.7 99.22 3/0 6/1 7/4.25 12.75 273 30.18
    Alliance 246.9 125.1 4/0 6/1 7/4.77 14.31 345 38.05
    Butte 312.8 158.6 266.8 26/7 19/3.26 16.30 437 48.76
    Canton 394.5 199.9 336.4 26/7 19/3.66 18.30 551 58.91
    Cairo 465.4 235.8 397.5 26/7 19/3.98 19.88 650 69.48
    Darien 559.5 283.5 477.0 26/7 19/4.36 21.79 781 83.52
    Elgin 652.4 330.6 556.5 26/7 19/4.71 23.54 911 97.42
    Flint 740.8 375.3 636.0 26/7 37/3.59 25.16 1035 108.21
    Greely 927.2 469.8 795.0 26/7 37/4.02 28.14 1295 135.47


    IEC 61089

    Code Number A2 Conductor A3 Conductor Max.D.C. Resistance of Conductor at 20ºC
    Number of Wires Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength Number of Wires Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength
    mm² - mm mm kg/km daN - mm mm kg/km daN Ω/km
    16 7 1.83 5.49 50.4 5.43 7 1.84 5.52 50.8 6.04 1.7896
    25 7 2.29 6.87 78.7 8.49 7 2.30 6.9 79.5 9.44 1.1453
    40 7 2.89 8.67 125.9 13.58 7 2.91 8.73 127.1 15.1 0.7158
    63 7 3.63 10.8 198.3 21.39 7 3.65 10.95 200.2 23.06 0.4545
    100 19 2.78 13.9 316.3 33.95 19 2.79 13.95 319.3 37.76 0.2877
    125 19 3.10 15.5 395.4 42.44 19 3.12 15.6 399.2 47.20 0.2302
    160 19 3.51 17.55 506.1 54.32 19 3.53 17.65 511.0 58.56 0.1798
    200 19 3.93 19.65 623.7 67.91 19 3.95 19.75 638.7 73.20 0.1439
    250 19 4.39 21.95 790.8 84.68 19 4.41 22.05 798.4 91.50 0.1151
    315 37 3.53 24.71 998.9 106.95 37 3.55 24.85 1008.4 115.29 0.0916
    400 37 3.98 27.86 1268.4 135.81 37 4.0 28 1280.5 146.4o 0.0721
    450 37 4.22 29.54 1426.9 152.79 37 4.24 29.68 1440.5 164.70 0.0641
    500 37 4.45 31.15 1585.5 169.76 37 4.47 31.29 1600.6 183.oo 0.0577
    560 61 3.67 33.03 1778.4 190.14 61 3.69 33.21 1795.3 204.95 0.0516
    630 61 3.89 35.01 2000.7 213.90 61 3.91 35.19 2019.8 230.58 0.0458
    710 61 4.13 37.17 2254.8 241.07 61 4.15 37.35 2276.2 259.86 0.0407
    800 61 4.38 39.42 2540.6 271.62 61 4.4 39.6 2564.8 282.80 0.0361
    900 91 3.81 41.91 2861.1 305.58 91 3.83 42.13 2888.3 329.40 0.0321
    1000 91 4.01 44.11 3179.0 339.53 91 4.03 44.33 3209.3 366.00 0.0289
    1120 91 4.25 46.75 3560.5 380.27 91 4.27 46.97 3594.4 409.92 0 0258
    1250 91 4.49 49.39 3973.7 424.41     - - - -


    BS EN50183

    Code Name Calculated
    Cross Section
    No..Dia.of Wires Overall Diameter Weight Rated Strength
      mm² No./mm mm kg/km kN
    Box 18.8 7/1.85 5.55 51.4 5.55
    Acacia 23.8 7/2.08 6.24 64.9 7.02
    Almond 30.1 7/2.34 7.02 82.2 8.88
    Cedar 35.5 7/2.54 7.62 96.8 10.46
    Deodar 42.2 7/2.77 8.31 115.2 12.44
    Fir 47.8 7/2.95 8.85 130.6 14.11
    Hazel 59.9 7/3.30 9.90 163.4 17.66
    Pine 71.6 7/3.61 10.8 195.6 21.14
    Holly 84.1 7/3.91 11.7 229.5 24.79
    Willow 89.7 7/4.04 12.1 245,0 26.47
    Oak 118.9 7/4.65 14.0 324.5 35.07
    Mulberry 150.9 19/3.18 15.9 414.3 44.52
    Ash 180.7 19/3.48 17.4 496.1 53.31
    Elm 211.0 19/3.76 18.8 579.2 62.24
    Poplar 239.4 37/2.87 20.1 659.4 70.61
    Sycamore 303.2 37/3.23 22.6 835.2 89.40
    Upas 362.1 37/3.53 24.7 997.5 106.82
    Yew 479.0 37/4.06 28.4 1319.6 141.31
    Totara 498.1 37/4.14 29.0 1372.1 146.93
    Rubus 586.9 61/3.50 31.5 1622.0 173.13
    Sorbus 659.4 61/3.71 33.4 1822.5 194.53
    Araucaria 821.1 61/4.14 37.3 2269.4 242.24
    Redwood 996.2 61/4.56 41.0 2753.2 293.88



    Din 48201

    Code number Calculated area Number of wires Diameter of wire Overall diameter of conductor Linear mass Rated tensile strength Max. DC resistance at 20ºC
    mm2 mm2   mm mm kg/km daN Ω/km
    16 15.89 7 1.70 5.1 43 444 2.0910
    25 24.25 7 2.10 6.3 66 677 1.3703
    35 34.36 7 2.50 7.5 94 960 0.9669
    50 49.48 7 3.00 9.0 135 1382 0.6714
    50 48.35 19 1.80 9.0 133 1350 0.6905
    70 65.81 19 2.10 10.5 181 1838 0.5073
    95 93.27 19 2.50 12.5 256 2605 0.3579
    120 116.99 19 2.80 14.0 322 3268 0.2854
    150 147.11 37 2.25 15.8 406 4109 0.2274
    185 181.62 37 2.50 17.5 500 5073 0.1842
    240 242.54 61 2.25 20.3 670 6774 0.1383
    300 299.43 61 2.50 22.5 827 8363 0.1120
    400 400.14 61 2.89 26.0 1104 11176 0.0838
    500 499.63 61 3.23 29.1 1379 13960 0.06709
    625 626.20 91 2.96 32.6 1732 17490 0.0540
    800 802.09 91 3.35 36.9 2218 22402 0.0418
    1000 999.71 91 3.74 41.1 2767 27922 0.0335

     

    AAAC All Aluminium Alloy Conductor 0

    AAAC All Aluminium Alloy Conductor 1

    Contact Details
    Luoyang Sanwu Cable Co., Ltd.,

    Contact Person: Alex Yang

    Tel: 86-13233918312

    Send your inquiry directly to us
    Other Products