Send Message

LUOYANG SANWU CABLE GROUP CO.,LTD.

Professional Cable and Conductor Manufacturer

Home ProductsAll Aluminium Conductor

16MM2 - 800MM2 AAC Conductor In Power Transmission Lines

16MM2 - 800MM2 AAC Conductor In Power Transmission Lines

  • 16MM2 - 800MM2 AAC Conductor In Power Transmission Lines
  • 16MM2 - 800MM2 AAC Conductor In Power Transmission Lines
16MM2 - 800MM2 AAC Conductor In Power Transmission Lines
Product Details:
Place of Origin: Henan
Brand Name: Sanwu
Certification: ISO CCC
Model Number: AAC-005
Payment & Shipping Terms:
Minimum Order Quantity: 1000M
Price: Negotiable
Packaging Details: New wooden drum, Reel, Circle or according to customer's request
Delivery Time: 1-15days
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 200 tons per day
Contact Now
Detailed Product Description
Name: AAC Conductor Conductor Material: Aluminum
Application: Power Transmission Lines Standard: ASTM,BS,DIN,AS/NZS,IEC, CSA
Port: Qingdao Packing: Wooden Drum
Supplier By Area: Asia,South America,South Africa MOQ: 10KM
Size: 16MM2 - 800MM2 Type Of Conductor:: Stranded
High Light:

800MM2 AAC Conductor

,

16MM2 AAC Conductor

,

Power Transmission AAC Conductor

16MM2 - 800MM2 AAC Conductor In Power Transmission Lines

 

Application:

Overhead transmission and primary and secondary distribution.

 

Applicable Standard:

IEC61089, ASTM B231, AAC BS215

 

Construction:

Aluminum 1350-H19 wires, concentrically stranded

 

16MM2 - 800MM2 AAC Conductor In Power Transmission Lines 0

16MM2 - 800MM2 AAC Conductor In Power Transmission Lines 1

 

Conductor (AAC and ACSR) have been widely used in power transmission lines with various voltage levels, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost, large transmission capacity. And they are also suitable for laying across rivers valleys and the places where special geographical features exist.

2. Service Performance

(1).The permissible long-time operating temperature for aerial conductor is 70oC.

(2).Under the circumstance that rare climate occurs and high ice coverage rate, the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.

(3).When connecting conductors, the conductor beside the connecting tube can’t be prominent. Otherwise, the force on the operating conductors will be unbalanced. After connectors are installed, the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.

(4).Under installation, the arc downing stress of all the conductors should be the same. With in the permissible distance of crossing buildings or dropping to the ground, the stress can be 10-15% higher than regular stress.

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.

Nominal

area

Stranding &wire diameter Approx Overall diameter Breaking Load DC Resistance at 20

Approx.

Weight

mm mm N Ω/km Kg/km
16 7/1.70 5.10 2840 1.802 43.5
25 7/2.15 6.45 4355 1.127 69.6
35 7/2.50 7.50 5760 0.8332 94.1
50 7/3.00 9.00 7930 0.5786 135..5
70 7/3.60 10.80 10950 0.4018 195.1
95 7/4.16 12.48 14450 0.3009 260.5
120 19/2.85 14.25 19420 0.2373 333.5
150 19/3.15 15.75 23310 0.1943 407.4
185 19/3.50 17.5 28440 0.1574 503.0
210 19/3.75 18.75 32260 0.1371 577.4
240 19/4.00 20.00 36260 0.1205 656.9
300 37/3.20 22.40 46850 0.09689 820.4
400 37/3.70 25.90 61150 0.07247 1097
500 37/4.16 29.12 76370 0.05733 1387
630 61/3.63 32.67 91940 0.04577 1744
800 61/4.10 36.90 115900 0.03588 2225

 

16MM2 - 800MM2 AAC Conductor In Power Transmission Lines 2