Send Message

LUOYANG SANWU CABLE GROUP CO.,LTD.

Professional Cable and Conductor Manufacturer

Home ProductsAerial Bundled Cable

Xlpe Aerial Bundle Conductor Cable Abc Overhead For Lighting

Xlpe Aerial Bundle Conductor Cable Abc Overhead For Lighting

  • Xlpe Aerial Bundle Conductor Cable Abc Overhead For Lighting
Xlpe Aerial Bundle Conductor Cable Abc Overhead For Lighting
Product Details:
Place of Origin: Henan
Brand Name: Sanwu
Certification: ISO CCC
Model Number: ABC CABLE
Payment & Shipping Terms:
Minimum Order Quantity: 1000M
Price: Negotiable
Packaging Details: wooden drums or as customers' requirements
Delivery Time: 1-15days
Payment Terms: T/T, L/C, Western Union, MoneyGram
Supply Ability: 200 tons per day
Contact Now
Detailed Product Description
Name: XLPE Aerial Bundled Cable Voltage: 0.6/1kv
Insulation: Xlpe Package: Wooden Drums
Supply Ability: 1500km Per Month Minimum Order Quantity: 5000meters
High Light:

xlpe aerial bundle conductor cable

,

overhead aerial bundle conductor cable

,

lighting aerial bundled cable

XLPE Aerial Bundled Cable Abc Overhead Cable For Lighting
 
Quick Details
 
(1)The rated voltage Uo/U is 0.6/1kV.
(2)The maximum rated temperature of cable conductor is 90℃.
(3)Cable shall be laid at no less than -20℃
(4)Minimum allowable bending radius of the cable: Cable with an outer diameter(D) less than 25mm shall have a diameter no less than 4D. The outer cable diameter(D) of 25mm and above shall be not less than 6D
 
Description:
The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminium 1350 are insulated with XLPE phase and neutral cores are laied up in a bundled with left hand lay. Cables are rated at 0.6/1(1.2) KV and conform to AS/NZS 3560.1
 
The main advantages of aerial bundled cables include:
1. ease of erection and stringing.
2. Practically no tree - trimming required.
3. Less maintenance.
 
ABC Cables technical characteristics:
Cores Nominal cross-sectional area Phase Conductors
insulation
Dia. Of cable R. of conductors at 20℃ Break strength of conductor
Ω/km KN
3C+1C mm2 Thickness (mm) mm Phase cores Neutral cores Phase cores Neutral cores
3C+1C 3x25+54.6 1.4 23.57 1.2 0.630 16.6 16.6
3C+1C 3x35+54.6 1.6 26.08 0.868 0.630 16.6 16.6
3C+1C 3x50+54.6 1.6 28.15 0.641 0.630 16.6 16.6
3C+1C 3x70+54.6 1.8 32.15 0.443 0.630 16.6 16.6
3C+1C 3x70+54.6 1.8 32.15 0.443 0.630 16.6 16.6
3C+1C 3x70+70 1.8 32.75 0.443 0.500 20.5 20.5
3C+1C 3x95+70 1.8 35.78 0.32 0.500 20.5 20.5
3C+1C 3x120+70 1.8 37.93 0.253 0.500 20.5 20.5
3C+1C 3x120+70 1.8 37.93 0.253 0.500 20.5 20.5
3C+1C 3x120+95 1.8 39.26 0.253 0.343 27.5 27.5
3C+1C 3x150+95 1.9 41.81 0.206 0.343 27.5 27.5

 

AS/NZS 0.6/1(1.2)KV Al/XLPE insulated aerial bundled cables

Contact Details
Luoyang Sanwu Cable Co., Ltd.,

Contact Person: Mandy Liu

Tel: +8613721689492

Send your inquiry directly to us
Other Products