Send Message

LUOYANG SANWU CABLE GROUP CO.,LTD.

Professional Cable and Conductor Manufacturer

Home ProductsXLPE Insulated Cable

1kv 4 AWG XLPE Insulated Cable Triplex Overhead Service Drop Cable

1kv 4 AWG XLPE Insulated Cable Triplex Overhead Service Drop Cable

  • 1kv 4 AWG XLPE Insulated Cable Triplex Overhead Service Drop Cable
1kv 4 AWG XLPE Insulated Cable Triplex Overhead Service Drop Cable
Product Details:
Place of Origin: Henan
Brand Name: Sanwu
Certification: ISO CCC
Model Number: LV ABC Cable (Aerial Bundle Cable)
Payment & Shipping Terms:
Minimum Order Quantity: 1000M
Price: USD 0.5 M
Packaging Details: To be negotiated
Delivery Time: 1-15days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 200 tons per day
Contact Now
Detailed Product Description
Name: Triplex Overhead Service Drop Cable Standard: Nfc 33209/ OECA/BS/NBR/GBT/SIP2/SIP4/SIP6
Insulation Material: XLPE ,PVC Specification: Will Send With Price To Your Email
Rated Voltage: 0.6/1kv Size: 4 AWG
High Light:

1kv XLPE Insulated Cable

,

Triplex Overhead Drop XLPE Insulated Cable

,

4 AWG XLPE Insulated Cable

4 AWG XLPE Insulated Cable Triplex Overhead Service Drop Cable

 

Distribution centers use exterior aluminum overhead cables. Through the weather head, they transport the electricity from the utility wires to the buildings. The cables also serve as service drop cables because of this specific role. There are three types of aluminum overhead cables: duplex, triplex, and quadruplex. In single-phase power lines, duplex cables are utilized, whereas in three-phase power lines, quadruplex cables are employed. Only triplex cables are utilized to deliver power to consumers from utility lines.

Soft aluminum 1350-H19 series is used to make aluminum conductor cables. Extruded thermoplastic polyethylene or cross-linked polyethylene is used as insulation to shield them from adverse outside weather conditions. The cables have a voltage rating of and an operating temperature of up to 75 degrees.


1kv 4 AWG XLPE Insulated Cable Triplex Overhead Service Drop Cable 0

1kv 4 AWG XLPE Insulated Cable Triplex Overhead Service Drop Cable 1
 
Product Description
Rated voltage
0.6/1kv
Specification
ABC
Structure
AWG or kcmi
Carrying wire core(acsr)
Phase conductor
insulation
 
Stell
Aluminium
Aluminium
xlpe
 
No.
Dia.
No.
Dia
Dia
No.
Dia
Dia
 
3*6AWG+1*6AWG
1
1.68
6
1.68
5.04
1
4.11
4.11
1.14
3*6AWG+1*6AWG
1
1.68
6
1.68
5.04
7
1.55
1.55
1.14
3*4AWG+1*4AWG
1
2.12
6
2.12
6.36
1
5.19
5.19
1.14
3*4AWG+1*4AWG
1
2.12
6
2.12
6.36
7
1.96
5.88
1.14
3*2AWG+1*2AWG
1
2.67
6
2.67
8.02
7
2.47
7.42
1.14
3*1/0AWG+1*1/0AWG
1
3.37
6
3.37
10.11
19
1.89
9.47
1.52
3*2/0AWG+1*2/0AWG
1
3.78
6
3.78
11.35
19
2.13
10.63
1.52
3*3/0AWG+1*3/0AWG
1
4.25
6
4.25
12.74
19
2.39
11.94
1.52
3*4/0AWG+1*4/0AWG
1
4.77
6
4.77
14.31
19
2.68
13.4
1.52
3*336.4+1*336.4
1
3.47
18
3.47
17.36
19
3.38
16.9
2.03
3*336.4+1*4/0AWG
1
4.77
6
4.77
14.31
19
3.38
16.9
2.03
1kv 4 AWG XLPE Insulated Cable Triplex Overhead Service Drop Cable 2
1kv 4 AWG XLPE Insulated Cable Triplex Overhead Service Drop Cable 3
*Applications:
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volt
or lower at a conductor temperature of 75℃ maximum.
 
 
 
 
Nominal cross section
Neutral core
Phase core
 
 
weight (kg/km)
Allowable ampacity (A)
AAC
 
LBS
AAC
Insulation thickness(mm)
 
XLPE
 
PE
NO
diameter
(mm)
NO
diameter(mm)
1*6AWG+1*6AWG
7
1.56
563
1
4.11
1.14
92
85
70
1*6AWG+1*6AWG
7
1.56
563
7
1.56
1.14
94
85
70
1*4AWG+1*4AWG
7
1.96
881
1
5.19
1.14
139
115
90
1*4AWG+1*4AWG
7
1.96
881
7
1.96
1.14
141
115
90
1*2AWG+1*2AWG
7
2.47
1350
7
2.47
1.14
216
150
120
1*1/0AWG+1*1/0AWG
7
3.12
1990
19
1.89
1.52
347
205
160
1kv 4 AWG XLPE Insulated Cable Triplex Overhead Service Drop Cable 4
1kv 4 AWG XLPE Insulated Cable Triplex Overhead Service Drop Cable 5

TRIPLEXSERVICEDROP-ALUMINUM CONDUCTOR:

*Applications:
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of75℃ maximum for polyethylene insulation or 90℃ maximum for crosslinked insulation.
 
 
 
AWG or kcmil
Bare Neutral Messenger
Phase Conductor
 
 
Weight kg/km
Allowable Ampacities(A)
AAC
Rated Strength lbs.
AAC
Insul. Thick. mm
 
XLPE
 
PE
NO.
Dia.mm
NO.
Dia.mm
2*6AWG+1*6AWG
7
1.56
563
1
4.11
1.14
146
85
70
2*6AWG+1*6AWG
7
1.56
563
7
1.56
1.14
150
85
70
2*4AWG+1*4AWG
7
1.96
881
1
5.19
1.14
219
115
90
2*4AWG+1*4AWG
7
1.96
881
7
1.96
1.14
224
115
90
2*2AWG+1*2AWG
7
2.47
1350
7
2.47
1.14
338
150
120
2*1/0AWG+1*1/0AWG
7
3.12
1990
7
3.12
1.52
544
205
160
2*1/0AWG+1*1/0AWG
7
3.12
1990
19
1.89
1.52
545
205
160
2*2/0AWG+l*2/0AWG
7
3.5
2510
7
3.5
1.52
671
235
185
2*3/0AWG+l*3/0AWG
19
2.39
3310
19
2.39
1.52
830
275
215
2*4/0AWG+l*4/0AWG
19
3.25
4020
19
3.25
1.52
1476
315
245
2*336.4+1*336.4
19
3.38
6146
19
3.38
2.03
1649
420
325
 
 
1kv 4 AWG XLPE Insulated Cable Triplex Overhead Service Drop Cable 6

Contact Details
Luoyang Sanwu Cable Co., Ltd.,

Contact Person: Alex Yang

Tel: 86-13233918312

Send your inquiry directly to us