| Place of Origin: | Henan |
| Brand Name: | Sanwu |
| Certification: | ISO |
| Model Number: | AAAC greely |
| Minimum Order Quantity: | 5000M |
|---|---|
| Price: | Negotiate |
| Packaging Details: | treated wooden drums / steel reels |
| Delivery Time: | two weeks |
| Payment Terms: | L/C, T/T, Western Union |
| Supply Ability: | 200 tons per day |
| Name: | All Aluminium Alloy Conductor | Size: | 1/0 AWG |
|---|---|---|---|
| Certification: | ISO Certification | Volatge: | Max 380kv |
| Standard: | B-230 ASTM AS BS CSA Standard | Feature: | High Tensile Strength |
| Highlight: | AAAC 593 Sqmm aluminum alloy conductor,70 Sqmm AAAC bare conductor wire,2500 Kcmil Lupine AAC cable |
||
AAAC-Aluminum Alloy Overhead Bare Conductor is mainly used as bare overhead transmission cable and as primary and secondary distribution cable. It is also suitable for laying across basins, rivers and valleys where special geographical teatures exist.
Service Performance
(1).The permissible long-time operating temperature for aerial conductor is 70oC.
(2).Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area,the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.
(3).When connecting conductors,the conductor beside the connecting tube cant be prominent.Otherwise,the force on the operating conductors will be unbalanced.After connectors are install,the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.
(4).Under installaion,the arc downing stress of all the conduct ors should be the same.With in the permissible distance of crossing buildings or dropping to the ground,the stress can be 10-15% higher than regular stress.
Material Standard Of All Aluminum Alloy Conductor
(1).The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889:1987).
(2).The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.
(3).Production can be arranged according to customers requirements for material standard,etc.
Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced
CONSTRUCTION PARAMETERS of 2/0 AWG All aluminium alloy conductor
| Nominal Area | Stranding | Overall | Weight | Rated | Electrical | Current | |
| Diameter | Strength | Resistance | Rating* | ||||
| AWG&MCM | mm2 | No.×mm | mm | kg/km | KN | Ω/Km | A |
| 6 | 13.2 | 7/1.55 | 4.65 | 36.2 | 4.18 | 2.5361 | 69 |
| 4 | 21.1 | 7/1.96 | 5.88 | 57.9 | 6.69 | 1.586 | 93 |
| 2 | 33.5 | 7/2.47 | 7.41 | 92 | 10.6 | 0.9987 | 123 |
| 0 | 53.5 | 7/3.12 | 9.36 | 146.8 | 17 | 0.62592 | 165 |
| 2/0 | 67.3 | 7/3.50 | 10.5 | 184.8 | 20.4 | 0.49738 | 190 |
| 3/0 | 84.9 | 7/3.93 | 11.79 | 233 | 25.7 | 0.3945 | 219 |
| 4/0 | 107 | 7/4.42 | 13.26 | 294.7 | 32.5 | 0.31188 | 253 |
| 250 | 126 | 19/2.91 | 14.55 | 346.7 | 38.8 | 0.26509 | 280 |
| 300 | 152 | 19/3.19 | 15.95 | 416.7 | 46.6 | 0.22059 | 313 |
| 350 | 178 | 19/3.45 | 17.25 | 487.3 | 52 | 0.1886 | 345 |
| 400 | 203 | 19/3.69 | 18.45 | 557.5 | 59.5 | 0.16486 | 375 |
| 450 | 228 | 19/3.91 | 19.55 | 626 | 66.8 | 0.14683 | 402 |
| 500 | 253 | 19/4.12 | 20.6 | 695 | 74.2 | 0.13224 | 429 |
| 550 | 279 | 37/3.10 | 21.7 | 766.2 | 83.9 | 0.11995 | 455 |
| 600 | 303 | 37/3.23 | 22.61 | 831.9 | 91 | 0.11049 | 478 |
| 650 | 330 | 37/3.37 | 23.59 | 905.5 | 94.9 | 0.1015 | 504 |
| 700 | 354 | 37/3.49 | 24.43 | 971.2 | 101 | 0.09464 | 525 |
| 750 | 381 | 37/3.62 | 25.34 | 1045 | 109 | 0.08796 | 549 |
| 800 | 404 | 37/3.73 | 26.11 | 1109 | 116 | 0.08285 | 569 |
| 900 | 456 | 37/3.96 | 27.72 | 1250 | 131 | 0.07351 | 612 |
| 1000 | 508 | 37/4.18 | 29.26 | 1393 | 146 | 0.06597 | 653 |
| 1250 | 631 | 61/3.63 | 32.67 | 1732 | 179 | 0.05306 | 743 |
| 1500 | 759 | 61/3.98 | 35.82 | 2082 | 215 | 0.04414 | 827 |
| 1750 | 886 | 61/4.30 | 38.7 | 2431 | 251 | 0.03781 | 904 |
(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
Applications:
AAAC conductors are primarily used in:
| Application Area | Purpose |
|---|---|
| Overhead power transmission lines | For medium and high voltage transmission systems |
| Urban and coastal areas | Where corrosion resistance is critical |
| Distribution lines | For long spans due to high strength and light weight |
| Renewable energy networks | Used in wind and solar farm transmission |
| Replacement of ACSR | Where lower line losses and improved durability are de |
Features:
About Us:
Luoyang Sanwu Cable Co., Ltd., with registered capital of 100 million RMB, is a high-tech development company for scientific research, industry producing and trading. After more than 20 years of development, our customers have spread to more than 40 countries and regions around the world, And more than 50% are old customers.The power cable,control cable,ABC cable,bare conductor(AAC/AAAC/ACSR) are more favorited by them.We are proud of our good quality---Sanwu CABLE.
FAQ:
Q: Are you trading company or manufacturer ?
A: We have our own factory and trading company, our factory have more than 10 years production experience.
Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. Or it is 15-20 days if the goods are not in stock, and it is according to quantity.
Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.
Q: What is your terms of payment ?
A: Payment<=1000USD, 100% in advance. Payment>=1000USD, 30% T/T in advance ,balance before shippment.L/C is also available.
Q:Have you ever supplied cables to our country ?
A: Cables have been supplied to many countries across the world such as USA, Australia, Switzerland, Singapore, Sri Lanka, the Philippines, Mongolia, UAE, Yemen, Iran, Iraq, Nigeria, Egypt, Lesotho, Cameroon, etc.
Contact Person: Alex Yang
Tel: 86-13233918312
PVC XLPE PE Insulated B-232 B-500 Aluminium Conductor Cable
Underground BS 215 Bare 95mm AAC Ant Conductor
ASTM BS All Aluminium Conductor For Overhead Transmission Line
Combined Light Weight ASTM DIN AACSR Conductor
Silver Coated Steel Core AACSR 0.6/1kv Overhead Aluminum Wire