Place of Origin: | Henan |
Brand Name: | Sanwu |
Certification: | ISO CCC |
Model Number: | YJLV |
Minimum Order Quantity: | 1000M |
---|---|
Price: | Negotiable |
Packaging Details: | Export steel or wooden drum |
Delivery Time: | 1-15days |
Payment Terms: | L/C, T/T, Western Union |
Supply Ability: | 200 tons per day |
Material: | Cu/Al+xlpe/pe/pvc | Voltage: | Under 35kv |
---|---|---|---|
Standard: | IEC,ASTM,BS,DIN,NFC,CSA | ||
Highlight: | YJV22 LV Power Cable,YJV LV Power Cable,YJV22 PVC Insulated cable |
Low Voltage XLPE PVC Insulated Armoured Flexible Electric (YJV/YJV22-0.6/1KV) Power Cable
Application:
This product is suitable for power transmission and distribution line of rated voltage (U0/U) 0.6/1.0KV line.
Technical Parameter:
When the cable is running normally, the Maximum temperature of conductor is 90℃; and is 250 ℃ when the short circuit (Max. last 5s) happens.
The ambient temperature of installation shall not lower than 0 degrees.
Minimum bending radius is 12 D (“D” refers to cable diameter)
Jacketed Aluminum Duplex Conductor Underground Power Cable Features and Benefits:
Jacketed Aluminum Duplex Conductor Underground Power Cable Applications:
Jacketed Aluminum Duplex Conductor Underground Power Cable Options:
Single Core Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
1*1.5 | 0.7 | 1.5 | 6 | 53 | 53 | ≤12.1 | ≤12.1 | 3.5 | 26 | 26 | 33 | 32 |
1*2.5 | 0.7 | 1.5 | 6 | 68 | ≤7.41 | 3.5 | 34 | 43 | ||||
1*4 | 0.7 | 1.5 | 7 | 87 | 64 | ≤4.61 | ≤7.41 | 3.5 | 44 | 35 | 56 | 42 |
1*6 | 0.7 | 1.5 | 7 | 110 | 73 | ≤3.08 | ≤4.61 | 3.5 | 56 | 45 | 70 | 54 |
Two Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
2*2.5 | 0.7 | 1.8 | 11.8 | 151 | 118 | ≤7.41 | ≤12.1 | 3.5 | 26 | 20 | 35 | 27 |
2*4 | 0.7 | 1.8 | 12.7 | 198 | 146 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
2*6 | 0.7 | 1.8 | 13.7 | 250 | 173 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
2*10 | 0.7 | 1.8 | 16.3 | 374 | 245 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Three Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
3×1.5 | 0.7 | 1.5 | 10 | 145 | - | ≤12.1 | - | 3.5 | 20 | - | 27 | - |
3×1.6 | 0.7 | 1.5 | 11 | 185 | 140 | ≤7.41 | ≤12.1 | 3.5 | 26 | 20 | 35 | 27 |
3×4 | 0.7 | 1.5 | 12 | 250 | 175 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
3×6 | 0.7 | 1.5 | 13 | 320 | 210 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
3×10 | 0.7 | 1.5 | 15 | 450 | 260 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Four Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
4×4 | 0.7 | 1.5 | 13 | 253 | 155 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
4×6 | 0.7 | 1.5 | 14 | 337 | 184 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
4×10 | 0.7 | 1.5 | 16 | 501 | 258 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Contact Person: Emily Wang
Tel: +8615139958913
PVC XLPE PE Insulated B-232 B-500 Aluminium Conductor Cable
Underground BS 215 Bare 95mm AAC Ant Conductor
ASTM BS All Aluminium Conductor For Overhead Transmission Line
Combined Light Weight ASTM DIN AACSR Conductor