Send Message

LUOYANG SANWU CABLE GROUP CO.,LTD.

Professional Cable and Conductor Manufacturer

Home ProductsLV Power Cable

YJV22 LV Power Cable

YJV22 LV Power Cable

  • YJV22 LV Power Cable
YJV22 LV Power Cable
Product Details:
Place of Origin: Henan
Brand Name: Sanwu
Certification: ISO CCC
Model Number: YJLV
Payment & Shipping Terms:
Minimum Order Quantity: 1000M
Price: Negotiable
Packaging Details: Export steel or wooden drum
Delivery Time: 1-15days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 200 tons per day
Contact Now
Detailed Product Description
Material: Cu/Al+xlpe/pe/pvc Voltage: Under 35kv
Standard: IEC,ASTM,BS,DIN,NFC,CSA
High Light:

YJV22 LV Power Cable

,

YJV LV Power Cable

,

YJV22 PVC Insulated cable

Low Voltage XLPE PVC Insulated Armoured Flexible Electric (YJV/YJV22-0.6/1KV) Power Cable

 

Application:

This product is suitable for power transmission and distribution line of rated voltage (U0/U) 0.6/1.0KV line.

Technical Parameter:

When the cable is running normally, the Maximum temperature of conductor is 90℃; and is 250 ℃ when the short circuit (Max. last 5s) happens.

The ambient temperature of installation shall not lower than 0 degrees.

Minimum bending radius is 12 D (“D” refers to cable diameter)

  • Complete Cable:
    • One phase conductor, and one neutral conductor are insulated with Extruded Cross-Linked Polyethylene (XLPE) and jacketed with Extruded High-Density Cross-Linked Polyethylene (HDXLPE)
    • Twisted cables form duplex assembly
    • Manufactured and tested in accordance with ANSI/ICEA Standard S-81-570
    • When specified, cable is produced in accordance with UL 854 and listed as a Type USE-2 cable
  • Conductors:
    • Class B compressed aluminum 1350-H19 meeting the requirements of ASTM B231 or B786
  • Insulation & Jacket:
    • Insulation is Extruded Black Cross-Linked Polyethylene (XLPE)
    • Jacket is Extruded High-Density Cross-Linked Polyethylene and meets requirements of ASTM D1248, Type III
    • The phase conductor is black, and the neutral conductor is black identified by three extruded yellow stripes.

Jacketed Aluminum Duplex Conductor Underground Power Cable Features and Benefits:

  • Insulation/Jacket system provide high degree of protection against insulation damage
  • For NEC-complying applications, the maximum conductor operating temp is 90°C in wet or dry locations
  • Also suitable for non-code-complying installations with a temperature of 90°C in wet or dry locations in accordance with ICEA specifications

Jacketed Aluminum Duplex Conductor Underground Power Cable Applications:

  • Intended for use in underground systems operated at 600 volts or less.

Jacketed Aluminum Duplex Conductor Underground Power Cable Options:

  • Aluminum 1350-H16 conductor
  • Copper conductors
  • Other neutral identification methods
  • CDC Combined Duct & Cable
  • Reeless Package
  • PE Insulated/HDPE Jacketed rated 75°C, Type UD-S
  • Type USE-2 per UL 44

Single Core Cable

Nominal cross section Nominal Thickness of Insulation Nominal thickness of Sheath Approx. Overall Diameter of Cable Approximate weight of cable Conductor DC resistance Test voltage Cable Current
In the air Buried in soil
Cu AL Cu AL Cu AL Cu AL
mm² mm mm mm Kg/km Kg/km Ω/km Ω/km kv/5min A A A A
1*1.5 0.7 1.5 6 53 53 ≤12.1 ≤12.1 3.5 26 26 33 32
1*2.5 0.7 1.5 6 68   ≤7.41 3.5 34 43
1*4 0.7 1.5 7 87 64 ≤4.61 ≤7.41 3.5 44 35 56 42
1*6 0.7 1.5 7 110 73 ≤3.08 ≤4.61 3.5 56 45 70 54

Two Cores Cable

Nominal cross section Nominal Thickness of Insulation Nominal thickness of Sheath Approx. Overall Diameter of Cable Approximate weight of cable Conductor DC resistance Test voltage Cable Current
In the air Buried in soil
Cu AL Cu AL Cu AL Cu AL
mm² mm mm mm Kg/km Kg/km Ω/km Ω/km kv/5min A A A A
2*2.5 0.7 1.8 11.8 151 118 ≤7.41 ≤12.1 3.5 26 20 35 27
2*4 0.7 1.8 12.7 198 146 ≤4.61 ≤7.41 3.5 34 27 45 36
2*6 0.7 1.8 13.7 250 173 ≤3.08 ≤4.61 3.5 43 35 57 46
2*10 0.7 1.8 16.3 374 245 ≤1.83 ≤3.08 3.5 60 47 77 59

Three Cores Cable

Nominal cross section Nominal Thickness of Insulation Nominal thickness of Sheath Approx. Overall Diameter of Cable Approximate weight of cable Conductor DC resistance Test voltage Cable Current
In the air Buried in soil
Cu AL Cu AL Cu AL Cu AL
mm² mm mm mm Kg/km Kg/km Ω/km Ω/km kv/5min A A A A
3×1.5 0.7 1.5 10 145 - ≤12.1 - 3.5 20 - 27 -
3×1.6 0.7 1.5 11 185 140 ≤7.41 ≤12.1 3.5 26 20 35 27
3×4 0.7 1.5 12 250 175 ≤4.61 ≤7.41 3.5 34 27 45 36
3×6 0.7 1.5 13 320 210 ≤3.08 ≤4.61 3.5 43 35 57 46
3×10 0.7 1.5 15 450 260 ≤1.83 ≤3.08 3.5 60 47 77 59

Four Cores Cable

Nominal cross section Nominal Thickness of Insulation Nominal thickness of Sheath Approx. Overall Diameter of Cable Approximate weight of cable Conductor DC resistance Test voltage Cable Current
In the air Buried in soil
Cu AL Cu AL Cu AL Cu AL
mm² mm mm mm Kg/km Kg/km Ω/km Ω/km kv/5min A A A A
4×4 0.7 1.5 13 253 155 ≤4.61 ≤7.41 3.5 34 27 45 36
4×6 0.7 1.5 14 337 184 ≤3.08 ≤4.61 3.5 43 35 57 46
4×10 0.7 1.5 16 501 258 ≤1.83 ≤3.08 3.5 60 47 77 59

185 Sqmm 240 Sqmm Low Voltage Power Cable With XLPE/PVC Insulation Material 0

Contact Details
Luoyang Sanwu Cable Co., Ltd.,

Contact Person: Emily Wang

Tel: +8615139958913

Send your inquiry directly to us
Other Products